Show simple item record

dc.contributor.authorGreen, Len_US
dc.date.accessioned2024-06-12T07:46:44Z
dc.date.available2024-06-11en_US
dc.date.issued23-06-2024
dc.identifier.citationMcCullagh J, Booth C, Lancut J, Platton S, Richards P, Green L. Every minute counts: A comparison of thawing times and haemostatic quality of plasma thawed at 37°C and 45°C using four different methods. Transfusion Medicine. 2024; 1-7. doi:10.1111/tme.13061
dc.identifier.issn0958-7578en_US
dc.identifier.urihttps://qmro.qmul.ac.uk/xmlui/handle/123456789/97400
dc.description.abstractBackground Having faster plasma thawing devices could be beneficial for transfusion services, as it may improve the rapid availability of thawed plasma for bleeding patients, and it might remove the need to have extended pre-thawed plasma: thus, reducing unnecessary plasma wastage. Study Design and Methods The aims of this study were to assess (a) the thawing times and (b) in vitro haemostatic quality of thawed plasma using Barkey Plasmatherm V (PTV) at 37 and 45°C versus Barkey Plasmatherm Classic (PTC) at 37 and 45°C, Sarstedt Sahara-III Maxitherm (SS-III) at 37°C and Helmer Scientific Thermogenesis Thermoline (TT) at 37°C. Haemostatic quality was assessed using LG-Octaplas at three different time points: baseline (5 min), 24 and 120 h after thawing. Results The thawing time (SD) of 2 and 4 units was significantly different between different thawers. PTV at 45°C was the fastest method for both 2 and 4 units (7.06 min [0.68], 9.6 min [0.87], respectively). SS-III at 37°C being the slowest method (24.69 min [2.09] and 27.18 min [4.4], respectively) (p = < 0.05). Baseline measurements for all assays showed no significant difference in the prothrombin time, fibrinogen, FII, FV, protein C activity or free protein S antigen between all methods tested. However, at baseline PTV (both 37°C and 45°C) had significantly higher levels of FVII, FVIII and FXI and shortened activated partial thromboplastin time. Discussion PTV was the quickest method at thawing plasma at both 37 and at 45°C. The haemostatic quality of plasma thawed at 45 versus 37°C was not impaired. Thawing frozen plasma at 45°C should be considered.
dc.publisherWileyen_US
dc.relation.ispartofTransfusion Medicineen_US
dc.rightsThis is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium,provided the original work is properly cited.
dc.titleEvery minute counts: a comparison of thawing times and haemostatic quality of plasma thawed at 37 o C and 45 o C using four different methodsen_US
dc.typeArticle
dc.rights.holder© 2024 The Author(s). Transfusion Medicine published by John Wiley & Sons Ltd on behalf of British Blood Transfusion Society.
dc.identifier.doi10.1111/tme.13061
pubs.notesNot knownen_US
pubs.publication-statusAccepteden_US
dcterms.dateAccepted2024-06-11en_US
rioxxterms.funderDefault funderen_US
rioxxterms.identifier.projectDefault projecten_US
qmul.funderScientific study to establish Barkey plasmatherm V::Barkey GmbH & Coen_US