Show simple item record

dc.contributor.authorYilmaz, Tuba
dc.date.accessioned2015-09-21T11:09:42Z
dc.date.available2015-09-21T11:09:42Z
dc.date.issued2013-09
dc.identifier.citationYilmaz, T. 2013. Wearable RF sensors for non-invasive detection of blood-glucose levels. Queen Mary University of London.en_US
dc.identifier.urihttp://qmro.qmul.ac.uk/xmlui/handle/123456789/8765
dc.descriptionPhDen_US
dc.description.abstractRadio frequency (RF) techniques have the potential to provide blood glucose readings through sensing the glucose dependent change in dielectric properties of the biological tissue. Such technique can enable much desired non-invasive and continuous monitoring of blood glucose level. In this work, we present realistic glucose dependence of dielectric properties as well as basic understanding of resonator behaviour while radiating towards the lossy biological tissue. To investigate the potential of RF techniques, two resonators, operating at microwave frequencies when placed radiating towards the biological tissue, are designed and fabricated. The spiral resonator is tested with liquid and semi-solid phantoms containing different amounts of sugar. An analytical formulation to retrieve the dielectric properties of the biological tissues is improved. In order to perform realistic tests, novel tissue mimicking materials for an extremely wide frequency range are proposed. Glucose dependance of the blood mimicking material dielectric properties are further investigated by adding realistic glucose amounts to the blood mimicking material and dielectric spectroscopy is performed. Next, a single pole Cole-Cole model is fitted to the median of the dielectric property measurements. In addition, a patch resonator is simulated with four-layered digital phantom and tested with the four-layered physical tissue mimicking phantom. Finally, a double parameter measurement platform is constructed by combining the patch resonator and a commercial force sensor to perform controlled experiments with humans. Also, the force dependant response of the patch resonator is quantified. Soda tests is performed on five subjects with the platform, all subjects were asked to apply the same level of force. Spiral resonator is also applied to examine the glucose changes of two human subjects during the soda test. The results suggests that, although the glucose-dependance of the dielectric properties is relatively small, the input impedance of a microwave resonator is still sensitive to such small alterations.en_US
dc.language.isoenen_US
dc.publisherQueen Mary University of Londonen_US
dc.subjectElectronic Engineeringen_US
dc.subjectRadio frequency techniquesen_US
dc.subjectDiabetesen_US
dc.subjectMedical engineeringen_US
dc.titleWearable RF sensors for non-invasive detection of blood-glucose levelsen_US
dc.typeThesisen_US
dc.rights.holderThe copyright of this thesis rests with the author and no quotation from it or information derived from it may be published without the prior written consent of the author


Files in this item

Thumbnail

This item appears in the following Collection(s)

  • Theses [4222]
    Theses Awarded by Queen Mary University of London

Show simple item record