Browsing Wolfson Institute of Preventive Medicine by Author "Waltham, RM"
Now showing items 1-2 of 2
-
A compact system for intraoperative specimen imaging based on edge illumination x-ray phase contrast
Havariyoun, G; Vittoria, FA; Hagen, CK; Basta, D; Kallon, GK; Endrizzi, M; Massimi, L; Munro, P; Hawker, S; Smit, B (2019) -
Detection of involved margins in breast specimens with X-ray phase-contrast computed tomography.
Massimi, L; Suaris, T; Hagen, CK; Endrizzi, M; Munro, PRT; Havariyoun, G; Hawker, PMS; Smit, B; Astolfo, A; Larkin, OJ (Nature Research, 2021-02-11)Margins of wide local excisions in breast conserving surgery are tested through histology, which can delay results by days and lead to second operations. Detection of margin involvement intraoperatively would allow the ...