Show simple item record

dc.contributor.authorDindyal, Shiva
dc.date.accessioned2015-09-21T15:39:15Z
dc.date.available2015-09-21T15:39:15Z
dc.date.issued2013
dc.identifier.citationDindyal, S. 2013. The role of contrast enhanced ultrasonography in post-operative surveillance of endovascular aortic aneurysm stent graft repair. Queen Mary University of Londonen_US
dc.identifier.urihttp://qmro.qmul.ac.uk/xmlui/handle/123456789/8782
dc.descriptionMD (Res)en_US
dc.description.abstractAbdominal aortic aneurysms are common and responsible for many deaths. They are treated increasingly by EndoVascular Aneurysm Repair (EVAR) rather than conventional surgery. Approximately 25% of EVAR patients require re-intervention to prevent aneurysm enlargement which can rupture despite previous repair. All EVAR patients undergo life-long surveillance for complications such as stent-graft migration or endoleak. Computed Tomography (CT) has been the ‘gold-standard’ for surveillance accounting for 65% of EVAR costs, and exposes patients to cumulative radiation and nephrotoxic contrast. Duplex Ultrasound Scanning (DUS) has been proposed as an alternative for surveillance with lesser cost and patient risk. However, clinical studies have reported varying results. The addition of microbubble contrast significantly improves endoleak detection rates, making it comparable with CT. The physical properties that affect endoleak detection with DUS have not been determined. It is also unknown specifically which endoleaks’ detection are improved by Contrast Enhanced Aortic Duplex UltraSound Scanning (CEADUSS). To investigate the physical properties of endoleaks, I constructed an EVAR phantom model with a simulated endoleak of variable velocity (fast/slow), position (near/far) and plane (anterior/lateral/posterior). Preliminary studies investigated the behavior of microbubble contrast in the phantom system, and then laboratory experiments tested subjects over 36 variable endoleaks using DUS and CEADUSS. These laboratory experiments were translated clinically with a pilot study of CEADUSS in 10 patients with endoleaks on CT not detected by DUS, undefined endoleak type or origin, or a sac enlargement with no endoleak present. My experiments reveal an insight into factors influencing ultrasound endoleak detection. With this knowledge, the use of these modalities for surveillance protocols can be increased, reducing current CT burden, radiation and nephrotoxic contrast exposure, and overall EVAR cost. Clinical assessment of an endoleak, specifically noting physical characteristics (plane, position and velocity) will improve detection and surveillance.en_US
dc.language.isoenen_US
dc.publisherQueen Mary University of London
dc.subjectlow pressure steam turbineen_US
dc.subjectaxial-radial diffuseren_US
dc.titleThe role of contrast enhanced ultrasonography in post-operative surveillance of endovascular aortic aneurysm stent graft repairen_US
dc.typeThesisen_US
dc.rights.holderThe copyright of this thesis rests with the author and no quotation from it or information derived from it may be published without the prior written consent of the author


Files in this item

Thumbnail

This item appears in the following Collection(s)

  • Theses [4235]
    Theses Awarded by Queen Mary University of London

Show simple item record