Show simple item record

dc.contributor.authorChang, Serene Hsi-Lin
dc.date.accessioned2015-09-15T15:40:27Z
dc.date.available2015-09-15T15:40:27Z
dc.date.issued2013-06
dc.identifier.citationChang, S.H. 2013. Clinical evaluation of a new optical fibre method of measuring oxygen saturation using photoplethysmograph signals reflected from internal tissues. Queen Mary University of London.en_US
dc.identifier.urihttp://qmro.qmul.ac.uk/xmlui/handle/123456789/8719
dc.descriptionMD (Res)en_US
dc.description.abstractTraditional methods of measuring oxygen saturation, e.g. pulse oximetry, depend on an adequate peripheral circulation and have a 20–30 second lag time before readings are obtained. This was a series of evaluations of novel optical probes, designed to measure oxygen saturation using fibreoptic technology directly from internal organs including the brain, oesophagus and organs with splanchnic circulations. A series of pilot studies were proposed and research ethics approval obtained to carry out studies in humans, under general anaesthesia, using these probes. Innovative reflectance probes were designed specifically for each of the four applications, so as to obtain potentially useful signals needed for signal processing, analysis and evaluation. Signals were successfully obtained from the brain, oesophagus and splanchnic region in almost all of the patients recruited. Good quality photoplethysmograph signals were recorded and these were translated into clinically meaningful values of oxygen saturation comparable to traditional methods of pulse oximetry. Overall, the signals were prone to movement artefacts as well as occasional interference from surgical diathermy and other sources. Nonetheless, the probes could prove to be a useful alternative to conventional external transmittance pulse oximetry methods as well as providing useful information regarding regional perfusion and oxygenation. The success of these pilot studies will form the basis of more research in the area and further development of such probes on the medical engineering front.en_US
dc.language.isoenen_US
dc.publisherQueen Mary University of Londonen_US
dc.subjectMedicineen_US
dc.subjectOxygen saturationen_US
dc.subjectMedical engineeringen_US
dc.titleClinical evaluation of a new optical fibre method of measuring oxygen saturation using photoplethysmograph signals reflected from internal tissuesen_US
dc.typeThesisen_US
dc.rights.holderThe copyright of this thesis rests with the author and no quotation from it or information derived from it may be published without the prior written consent of the author


Files in this item

Thumbnail

This item appears in the following Collection(s)

  • Theses [4209]
    Theses Awarded by Queen Mary University of London

Show simple item record