Show simple item record

dc.contributor.authorShahdad, SAen_US
dc.contributor.authorMcCabe, JFen_US
dc.contributor.authorWassell, RWen_US
dc.date.accessioned2023-01-31T09:13:04Z
dc.date.available2006-05-05en_US
dc.date.issued2007-08en_US
dc.identifier.issn0957-4530en_US
dc.identifier.urihttps://qmro.qmul.ac.uk/xmlui/handle/123456789/84138
dc.description.abstractThe effect of various food-simulating solvents on the hardness of denture teeth after varying storage times, using a Martens hardness test was determined. Martens hardness (HM) was assessed at baseline and during storage up to 1 month in distilled water (DW), peppermint oil (PO), heptane (HT) and 75% ethanol (ET) for four commercially-available denture teeth; Vivodent (VIV), Double-cross-linked Postaris (DCL), Orthosit (ORT), Candulor porcelain (POR) and two polymer based experimental denture teeth: Experimental 1 (EXP1); a hybrid nanocomposite with two different sized silanated filler particles and Experimental 2 (EXP2); containing an organic copolymer based upon urethanedimethacrylate and polymethyl methacrylate. Hardness [mean (sd)] at baseline was: VIV 142 (1), DCL 142 (1), ORT 209 (9), POR 2926 (101), EXP1 285 (11), and EXP2 146 (12). One-way ANOVA using Tukey's test on polymer-based materials showed that the hardness values of ORT and EXP1 were significantly higher than those of VIV, DCL and EXP2 (P < 0.05). Moreover, EXP1 had a significantly higher hardness value than ORT (P < 0.05). Except for EXP1, all polymer based materials showed a significant drop in hardness after storage in ET (P < 0.05). Specimens stored in water, heptane and peppermint oil showed minor fluctuations in hardness, which were not statistically significant.en_US
dc.format.extent1599 - 1603en_US
dc.languageengen_US
dc.relation.ispartofJ Mater Sci Mater Meden_US
dc.subjectDental Restoration Wearen_US
dc.subjectDenture Designen_US
dc.subjectDenturesen_US
dc.subjectEquipment Failure Analysisen_US
dc.subjectFooden_US
dc.subjectHardnessen_US
dc.subjectHardness Testsen_US
dc.subjectSolventsen_US
dc.subjectSurface Propertiesen_US
dc.titleDevelopments in denture teeth to prevent softening by food solvents.en_US
dc.typeArticle
dc.identifier.doi10.1007/s10856-007-3043-4en_US
pubs.author-urlhttps://www.ncbi.nlm.nih.gov/pubmed/17483891en_US
pubs.issue8en_US
pubs.notesNot knownen_US
pubs.publication-statusPublisheden_US
pubs.volume18en_US
dcterms.dateAccepted2006-05-05en_US
qmul.funderAn investigation into the wear of artificial denture teeth used in implant-retained prostheses.::NHS UKen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record