Show simple item record

dc.contributor.authorEvans, RJ
dc.contributor.authorLavin, B
dc.contributor.authorPhinikaridou, A
dc.contributor.authorChooi, KY
dc.contributor.authorMohri, Z
dc.contributor.authorWong, E
dc.contributor.authorBoyle, JJ
dc.contributor.authorKrams, R
dc.contributor.authorBotnar, R
dc.contributor.authorLong, NJ
dc.date.accessioned2021-11-09T10:50:38Z
dc.date.available2020-05-06
dc.date.available2021-11-09T10:50:38Z
dc.date.issued2020
dc.identifier.citationEvans RJ, Lavin B, Phinikaridou A, Chooi KY, Mohri Z, Wong E, Boyle JJ, Krams R, Botnar R, Long NJ. Targeted Molecular Iron Oxide Contrast Agents for Imaging Atherosclerotic Plaque. Nanotheranostics 2020; 4(4):184-194. doi:10.7150/ntno.44712.en_US
dc.identifier.issn2206-7418
dc.identifier.urihttps://qmro.qmul.ac.uk/xmlui/handle/123456789/75104
dc.description.abstractOverview: Cardiovascular disease remains a leading cause of death worldwide, with vulnerable plaque rupture the underlying cause of many heart attacks and strokes. Much research is focused on identifying an imaging biomarker to differentiate stable and vulnerable plaque. Magnetic Resonance Imaging (MRI) is a non-ionising and non-invasive imaging modality with excellent soft tissue contrast. However, MRI has relatively low sensitivity (micromolar) for contrast agent detection compared to nuclear imaging techniques. There is also an increasing emphasis on developing MRI probes that are not based on gadolinium chelates because of increasing concerns over associated systemic toxicity and deposits1. To address the sensitivity and safety concerns of gadolinium this project focused on the development of a high relaxivity probe based on superparamagnetic iron oxide nanoparticles for the imaging of atherosclerotic plaque with MRI. With development, this may facilitate differentiating stable and vulnerable plaque in vivo. Aim: To develop a range of MRI contrast agents based on superparamagnetic iron oxide nanoparticles (SPIONs), and test them in a murine model of advanced atherosclerosis. Methods: Nanoparticles of four core sizes were synthesised by thermal decomposition and coated with poly(maleicanhydride-alt-1-octadecene) (PMAO), poly(ethyleneimine) (PEI) or alendronate, then characterised for core size, hydrodynamic size, surface potential and relaxivity. On the basis of these results, one candidate was selected for further studies. In vivo studies using 10 nm PMAO-coated SPIONs were performed in ApoE -/- mice fed a western diet and instrumented with a perivascular cuff on the left carotid artery. Control ApoE -/- mice were fed a normal chow diet and were not instrumented. Mice were scanned on a 3T MR scanner (Philips Achieva) with the novel SPION contrast agent, and an elastin-targeted gadolinium agent that was shown previously to enable visualisation of plaque burden. Histological analysis was undertaken to confirm imaging findings through staining for macrophages, CX3CL1, elastin, tropoelastin, and iron. Results: The lead SPION agent consisted of a 10 nm iron oxide core with poly(maleicanhydride-alt-1-octadecene), (-36.21 mV, r2 18.806 mmol-1/s-1). The irregular faceting of the iron oxide core resulted in high relaxivity and the PMAO provided a foundation for further functionalisation on surface -COOH groups. The properties of the contrast agent, including the negative surface charge and hydrodynamic size, were designed to maximise circulation time and evade rapid clearance through the renal system or phagocytosis. In vitro testing showed that the SPION agent was non-toxic. In vivo results show that the novel contrast agent accumulates in similar vascular regions to a gadolinium-based contrast agent (Gd-ESMA) targeted to elastin, which accumulates in plaque. There was a significant difference in SPION signal between the instrumented and the contralateral non-instrumented vessels in diseased mice (p = 0.0411, student's t-test), and between the instrumented diseased vessel and control vessels (p = 0.0043, 0.0022, student's t-test). There was no significant difference between the uptake of either contrast agent between stable and vulnerable plaques (p = 0.3225, student's t-test). Histological verification was used to identify plaques, and Berlin Blue staining confirmed the presence of nanoparticle deposits within vulnerable plaques and co-localisation with macrophages. Conclusion: This work presents a new MRI contrast agent for atherosclerosis which uses an under-explored surface ligand, demonstrating promising properties for in vivo behaviour, is still in circulation 24 hours post-injection with limited liver uptake, and shows good accumulation in a murine plaque model.en_US
dc.format.extent184 - 194
dc.languageeng
dc.publisherIvyspring International Publisheren_US
dc.relation.ispartofNanotheranostics
dc.rightsThis is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/). See http://ivyspring.com/terms for full terms and conditions.
dc.subjectMRI contrast agentsen_US
dc.subjectatherosclerosisen_US
dc.subjectsuperparamagnetic iron oxide nanoparticlesen_US
dc.subjectvulnerable plaqueen_US
dc.subjectAnimalsen_US
dc.subjectCarotid Arteriesen_US
dc.subjectContrast Mediaen_US
dc.subjectDiet, High-Faten_US
dc.subjectFemaleen_US
dc.subjectMagnetic Resonance Imagingen_US
dc.subjectMagnetite Nanoparticlesen_US
dc.subjectMiceen_US
dc.subjectMice, Knockouten_US
dc.subjectMolecular Imagingen_US
dc.subjectPlaque, Atheroscleroticen_US
dc.titleTargeted Molecular Iron Oxide Contrast Agents for Imaging Atherosclerotic Plaque.en_US
dc.typeArticleen_US
dc.rights.holder© The author(s).
dc.identifier.doi10.7150/ntno.44712
pubs.author-urlhttps://www.ncbi.nlm.nih.gov/pubmed/32637296en_US
pubs.issue4en_US
pubs.notesNot knownen_US
pubs.publication-statusPublished onlineen_US
pubs.publisher-urlhttp://doi.org/10.7150/ntno.44712
pubs.volume4en_US
dcterms.dateAccepted2020-05-06
rioxxterms.funderDefault funderen_US
rioxxterms.identifier.projectDefault projecten_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record