Show simple item record

dc.contributor.authorSpeedie, JMMen_US
dc.contributor.authorMansour, Den_US
dc.contributor.authorLandy, Ren_US
dc.contributor.authorClement, KMen_US
dc.date.accessioned2017-01-09T11:59:15Z
dc.date.available2016-07-05en_US
dc.date.issued2016-10en_US
dc.date.submitted2016-12-13T15:02:35.794Z
dc.identifier.urihttp://qmro.qmul.ac.uk/xmlui/handle/123456789/18446
dc.description.abstractBACKGROUND: Pain at intrauterine contraception (IUC) fitting may be a deterrent for women and any reduction in discomfort would be likely to be beneficial to both women and clinicians. AIM: This study investigated the associated pain and the ease of use of two different stabilising forceps at the time of IUC placement. DESIGN: Single-blinded randomised controlled trial. One hundred parous women aged 18-50 years who had undergone at least one vaginal delivery were recruited. SETTING: An integrated sexual health service in the North of England. METHODS: Women were randomised to the use of either a Littlewoods forceps or a single-toothed tenaculum forceps to stabilise the cervix at the time of IUC placement. Pain levels were measured at forceps application, IUC insertion, and 5 and 10 minutes post-procedure using a visual analogue scale (VAS). A clinician graded ease of use of the forceps and any associated bleeding. Wilcoxon rank-sum tests were used to compare pain levels between the two forceps groups. Linear regression was used when adjusting for potential confounders. RESULTS: Mean VAS scores were similar at forceps application (p=0.52), IUC fitting (p=0.10) and at 5 minutes (p=0.32). There was a statistical difference in the degree of pain experienced at 10 minutes in the tenaculum group (p=0.01). Physicians found both forceps easy to use and there was no difference in bleeding (p=0.49). CONCLUSIONS: Parous women who have had a vaginal delivery can be reassured that IUC fitting is well tolerated. Pain scores were not affected by the type of forceps used to stabilise the cervix at IUC placement. Both forceps investigated were easy to use.en_US
dc.format.extent241 - 246en_US
dc.languageengen_US
dc.language.isoenen_US
dc.relation.ispartofJ Fam Plann Reprod Health Careen_US
dc.subjectintrauterine devicesen_US
dc.subjectintrauterine systemsen_US
dc.subjectstatisticsen_US
dc.titleA randomised trial comparing pain and ease of use of two different stabilising forceps for insertion of intrauterine contraception.en_US
dc.typeArticle
dc.identifier.doi10.1136/jfprhc-2016-101446en_US
pubs.author-urlhttps://www.ncbi.nlm.nih.gov/pubmed/29175841en_US
pubs.issue4en_US
pubs.notesNot knownen_US
pubs.publication-statusPublisheden_US
pubs.volume42en_US
dcterms.dateAccepted2016-07-05en_US


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record