Show simple item record

dc.contributor.authorAl Shayeb, KNen_US
dc.contributor.authorTurner, Wen_US
dc.contributor.authorGillam, DGen_US
dc.date.accessioned2015-08-03T08:44:21Z
dc.date.available2014-02-11en_US
dc.date.issued2014-04en_US
dc.identifier.issn1013-9052en_US
dc.identifier.urihttp://qmro.qmul.ac.uk/xmlui/handle/123456789/8081
dc.description© 2014, Accuracy and reproducibility of probe forces during simulated periodontal pocket depth measurements. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/
dc.description.abstractAIM: The aim of the present study was to measure the accuracy and reproducibility of probe forces in simulated assessments of periodontal pocket depth. The study included experienced and inexperienced examiners and used manual and pressure-sensitive probes. MATERIALS AND METHODS: Sixty-one participants were divided into seven groups and asked to probe selected anterior and posterior sites with three different probes (Williams 14W, Chapple UB-CF-15, and Vivacare TPS probes). The model was positioned on a digital electronic balance to measure force, which was recorded initially and after 15 min. Probe preferences were recorded. Accuracy was measured by comparing to a standardized 25 g force, and reproducibility was calculated for all duplicate measurements. RESULTS: The Vivacare probe produced the most accurate and most reproducible forces, whereas the Williams probe produced the least accurate and least reproducible forces. Probe forces were lighter at anterior sites compared to posterior sites at baseline. Probe forces were reduced at both sites after 15 min compared to baseline. CONCLUSIONS: Vivacare TPS periodontal probes are more accurate and reproducible than Chapple and Williams probes. Many clinicians in this study preferred the Chapple probe.en_US
dc.format.extent50 - 55en_US
dc.languageengen_US
dc.relation.ispartofSaudi Dent Jen_US
dc.subjectAccuracyen_US
dc.subjectForceen_US
dc.subjectPeriodontal probesen_US
dc.subjectProbingen_US
dc.subjectReproducibilityen_US
dc.titleAccuracy and reproducibility of probe forces during simulated periodontal pocket depth measurements.en_US
dc.typeArticle
dc.identifier.doi10.1016/j.sdentj.2014.02.001en_US
pubs.author-urlhttps://www.ncbi.nlm.nih.gov/pubmed/25408596en_US
pubs.issue2en_US
pubs.notesNot knownen_US
pubs.publication-statusPublisheden_US
pubs.volume26en_US
dcterms.dateAccepted2014-02-11en_US


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record